SC4 Encyclopaedia

This page pertains to the format of the Plumbing Simulator Subfile within Savegame files. This file has Type ID 0x298f9b2d. This particular subfile was decoded by .

The plumbing simulator contains a few lists:

Structure

DWORD   Size
DWORD   CRC
DWORD   Memory address
DWORD   Major version (0x0004)
DWORD   Pointer to SimGrid
DWORD   0x49b9e602 (Type ID of SimGridUint8)
DWORD   Pointer to SimGrid
DWORD   0x49b9e602 (Type ID of SimGridUint8)
DWORD   xSize of city (64, 128 or 256)
DWORD   zSize of city (64, 128 or 256)
    BYTE    A byte for every tile in the city. Order is (0, 0), (1, 0), ...
DWORD   Revision. Seems like every time you change something to the plumbing situation
    (such as building a water tower, laying pipes, ...) this value is increased by 1.
DWORD   Unknown (mostly 0x00000000, seen 24 and 42 as well).
DWORD x 2   Unknown (only seen 0x00000000)
DWORD   Number of water related buildings
DWORD   Unknown (only seen 0x00000000)

    # Repeat for amount of buildings
    DWORD   X coordinate of anchor building
    DWORD   Z coordinate of anchor building
    DWORD   Min X coordinate of lot
    DWORD   Min Z coordinate of lot
    DWORD   Max X coordinate of lot
    DWORD   Max Z coordinate of lot
    DWORD   Water produced per month
    DWORD   Actual water produced per month (uses degradation)
    DWORD   Pointer to entry in building subfile
    DWORD   0xa9bd882d (Type ID of building subfile)

DWORD x 9   Unknown (only seen 0x00000000)
BYTE    Unknown (only seen 0x02)
DWORD   Unknown (only seen 0x00000000)
DWORD   City size (64, 128 or 256)
DWORD x 3   Unknown (only seen 0x00000000)
DWORD   X size of city minus 1 (63, 127 or 255)
DWORD   Z size of city minus 1 (63, 127 or 255)
DWORD   Water filter capacity?
DWORD   Unknown (only seen 0x00000000)
DWORD   Amount of pipe segments to follow
DWORD x 2 (Unknown, only  seen 0x00000000)
    
    # Repeat for amount of pipe sections
    DWORD   Pointer to Pipe Occupant record
    DWORD   0x49c05b9f (Type ID of PipeOccupant)

DWORD   Pointer to Department Budget record
DWORD   0xe990bffc (Type Id of Department Budget)
DWORD   Total water produced
DWORD   Unknown (only seen 0x00000000)
DWORD   Actual filter capacity, taking into account degradation?
DWORD x 5   Unknown (only seen 0x00000000)